Reliability of a new computerized equinometer based on Silfverskiöld test to measure gastrocnemius tightness - ERPHAN - Equipe de Recherche Paramédicale sur le Handicap NeuroMoteur Accéder directement au contenu
Article Dans Une Revue PLoS ONE Année : 2023

Reliability of a new computerized equinometer based on Silfverskiöld test to measure gastrocnemius tightness

Matthieu Lalevée
Julien Beldame
  • Fonction : Auteur
H. Brunel
  • Fonction : Auteur
F. Dujardin
  • Fonction : Auteur

Résumé

Background Several tools exist to measure tightness of the gastrocnemius muscles; however, few of them are reliable enough to be used routinely in the clinic. The primary objective of this study was to evaluate the intra- and inter-rater reliability of a new equinometer. The secondary objective was to determine the load to apply on the plantar surface of the metatarsal heads to achieve the highest reliability when measuring gastrocnemius tightness. Methods The equinometer consisted of a goniometer and an electronic dynamometer, hooked up to a computer. Three raters carried out three trials of passive dorsiflexion by applying controlled pressure to the metatarsal heads of both ankles in 29 healthy subjects under two experimental conditions: knee extended (KE) and knee flexed at 30 degrees (KF). The equinometer continuously recorded the ankle dorsiflexion values (in ̊) corresponding to each 1 N interval of plantar pressure between 4 N and 20 N. The intra- and inter-rater reliability of the ankle dorsiflexion were evaluated through the intra-class correlation (ICC) coefficients in each of the pressure intervals. Results The intra-rater ICC in KE and KF was between 0.84 and 0.98. The inter-rater ICC in KE and KF was between 0.59 and 0.92. The pressure interval between 14 N and 15 N had the highest intra-rater (ICC = 1) and inter-rater reliability (0.87≤ICC≤0.99). A more refined analysis of this interval found that a load of 14.5 N yielded the best reliability. Conclusions This compact equinometer has excellent intra-rater reliability and moderate to good interrater reliability. Since this reliability is optimal in the 14–15 N range, this load should be used going forward in clinical practice, especially when aiming to define a pathological threshold for tightness of the gastrocnemius muscles.
Fichier principal
Vignette du fichier
journal.pone.0284279.pdf (1.71 Mo) Télécharger le fichier
Origine Fichiers éditeurs autorisés sur une archive ouverte

Dates et versions

hal-04122850 , version 1 (29-05-2024)

Licence

Identifiants

Citer

Lucas Martinez, Matthieu Lalevée, Julien Beldame, M. L’hermette, H. Brunel, et al.. Reliability of a new computerized equinometer based on Silfverskiöld test to measure gastrocnemius tightness. PLoS ONE, 2023, 18 (4 April), ⟨10.1371/journal.pone.0284279⟩. ⟨hal-04122850⟩
7 Consultations
0 Téléchargements

Altmetric

Partager

Gmail Mastodon Facebook X LinkedIn More